12 HP function generator
Head
Each Head is an independent route through the stage field. Place one to eight directly left of MIDI or Program.
Transport and status
| Control | Action |
|---|---|
| Start | Run or resume. The input also supplies Sustain gate level and Enable threshold. |
| Stop | Stop immediately. |
| Advance | Force the next stage according to direction and region. |
| Reset | Return to the First stage of the active region. |
| Display | Latch this head as Program's live edit display. Press again, or use Select, to release. |
Green means running, yellow means holding or waiting for a selected clock source, and red means stopped or in Continuous addressing.
Addressing
| Control | Choices |
|---|---|
| Address | 0–10 V position knob; scaling is selected on Program. |
| Int / Ext | Use the knob or Address CV input. |
| Mode | Strobe loads the addressed stage once; Sequential clocks through stages; Continuous sweeps the stage field directly from address. |
Playback
| Control | Choices |
|---|---|
| Direction | Forward, Reverse, Pendulum, Random, Brownian |
| Clock | Internal stage time, external CLK input, MIDI Clock, or Virtual Clock from MIDI CC |
| Div / Mult | /16, /8, /4, /2, ×1, ×2, ×4, ×8, ×16. Sets the base clock rate. |
| Time CV | Bipolar attenuverter for the Time CV input, scaling all stage intervals for this head. |
| Time Mult | Continuous ×0.5 to ×4, with ×1 at center. Scales each resulting interval. |
| Loop | One-shot, First–Last region, or full chain |
Inputs
| Input | Purpose |
|---|---|
| Start | Start pulse; Sustain gate; Enable >5 V threshold. |
| Stop | Stop pulse. |
| Advance | Force one stage transition. |
| Strobe | Load the stage selected by Address. |
| Address | External address voltage when Ext is selected. |
| CLK | External clock edges. |
| Time | Per-head modulation of interval duration. |
| Reset | Return to the First stage of the active region. |
Outputs
| Output | Signal |
|---|---|
| CV | Rendered stage voltage; 1 V/oct when the stage is quantized. |
| Time | Current stage's time-slider value as CV. |
| Ref | Downward ramp spanning the interval. |
| All | Pulse at every stage entry. |
| P1 / P2 | Programmed stage gates. |
| EOC | End-of-cycle or stop event. |
MIDI control
The MIDI module's context menu sets the instance's contiguous HEAD input-channel range. The channel selects this Head by its position in the chain. The Head context menu shows its Head number, last received CC, and Follow MIDI transport setting. When enabled, MIDI Start, Stop, and Continue affect this Head.
For per-stage SYNC timing, the Stage Time companion sets the Program-selected stage to FREE or SYNC. In SYNC, the stage's time slider selects a note division; this Head's clock source and Div / Mult supply the base clock rate.